THROMBEKTOMY UP TO 24H?

- FAST THERAPY DECISION WITH MRAY -

AI image analysis: mRay-VEOcore

Optimized CT/MRI perfusion analysis

Stroke is one of the most common causes of death and a leading cause of severe, permanent disability. Thrombectomy offers a new and improved treatment option. mRay-VEOcore supports your decision-making with automated AI-based analysis — because “time is brain”!

mRay-VEOcore

  • Guideline-compliant fully automated evaluation of perfusion measurements within three minutes.
  • Display DEFUSE-3 inclusion criteria as suggested in ESO Guideline [01.2019]:
    infarct core volume, penumbra volume, mismatch ratio.
  • Intuitive representation in a 3D overview: infarct core (red) and hypoperfusion (yellow) as colored overlay, representation of CBF and Tmax.
  • Automated e-ASPECTS analysis
  • Quantitative results for the quality of the automatic evaluation: warning in case of detected patient movement or incorrect contrast medium injection.
  •  
ki basierte perfusionsanlyse screenshot mray veocore
Full 3D data set with hypoperfusion (TMAX>6s)
ki basierte perfusionsanalyse mRay VEOCORE Motion Correction
Motion correction: warning when patient movement is detected

Fast communication

Thanks to full integration in mRay, all parties involved are informed in real time and can coordinate on the case regardless of location, of course also via mobile devices. Therapy decisions are made quickly and still evidence-based according to the European Stroke Organisation (ESO).

The acquisition is cost-effective, available as a standalone or as a package.

Development with users

mRay VEOcore is a joint project by VEObrain, University Medical Center Freiburg, and mbits – developed on-site according to user needs. By integrating it into mRay and enabling rapid image data exchange, optimal stroke care becomes possible. After all: Time is Brain!

News about mRay VEOcore

New Webinar Available: Dr. Ingmar Gergel gives an exciting overview of mRay VEOcore’s newest features in this video.

  • Perfusion Analysis by mRay VEOcore
  • Outputs & Demo of mRay VEOcore
  • Analysis of Results
  • e-ASPECTS on NCCT
  • Multimodal Stroke Imaging
  • Radiation Reduction

mRay VEOcore on deepcOS®

mRay VEOcore is now available via the AI platform deepcOS® and the deepc AI Marketplace – centrally integrated into a growing ecosystem of validated AI solutions for hospitals and radiology facilities. Learn more

Everything at a glance with mRay

CBF/Mismatch mit MT Indication mRay VEOcore
mRay VEOcore: CBF/mismatch with MT indication
Quality control: bolus detection and patient movement

Recommended by Experts

This is what mRay users say

Contact us

Interested in mRay?

Get in touch with us via email or phone – we’re happy to assist you. Alternatively, you can explore mRay yourself and discover the countless ways our medical app can be used in everyday clinical practice.

FAQs about Perfusion Analysis

You may already find some answers here

Perfusion analysis of brain images allows visualization and quantification of low-perfusion tissue (penumbra), non-perfusion tissue (core tissue), and the mismatch ratio between the two values. The calculated values can be used to support decision making based on the assessment of the extent of tissue damage.

Usually, the evaluation can be started automatically in the standard configuration. If required, the possibility for manual evaluation can be set up.

EN

Vielen Dank für Ihre Anmeldung

In Kürze erhalten Sie eine E-Mail, mit der Sie das Abonnement unseres Newsletters bestätigen können.